PREVIEW / NOT FOR MANUFACTURE

Nidec Drives and Controls · FLEXWAVE WP / WPC

WPC-35-100-CR

Component set harmonic reducer configuration with a 100:1 reduction ratio and vendor-specific / unresolved.

Component setconfigurationeligiblereviewed
Add to compare

This record is a source-backed research sample, not yet a verified orderable SKU.

Normalized data

Specifications

Values shown in standard units

Performance

Reduction ratio100 :1
Rated torqueNot reported for this source termNot published
Nominal Output TorqueAt 2,000 rpm input10 Nm
Repeated peak torqueNot published
Peak torque at start/stopNot published
Maximum average load torqueNot published
Maximum momentary torqueNot published
Instantaneous torqueNot published
Emergency-stop torque70 Nm
Maximum allowable peak torqueNot published
Maximum input speed — source generic8,500 rpm
Maximum input speed — greaseNot published
Maximum input speed — oilNot published
Average input speed limit — greaseNot published
Average input speed limit — oilNot published
Rated / nominal input speed3,000 rpm

Integration

Product formComponent set
Vendor form labelcomponent_set
Input configurationVendor-specific / unresolved
Frame sizeVendor code · explanation only in v0.135
Mass0.1 kg
Input moment of inertia0.0362 source scale
Rated service life10000 h

All source-labelled observations

Framesource specific.frame size · explanation only35
Ratio Rreduction ratio · filter-eligible100
Nominal Output Torquenominal output torque at input speed · filter-eligible10 Nm
Maximum Output Torquesource specific.maximum output torque nm · explanation only36 Nm
Emergency Stop Torquesource specific.emergency stop torque nm · explanation only70 Nm
Nominal Input Speednominal input speed · filter-eligible3000 rpm
Maximum Input Speedmaximum input speed.unspecified lubricant · filter-eligible8500 rpm
Lifesource specific.life h · explanation only10000 h
Weightmass.exact · filter-eligible0.1 kg
Moment of Inertiasource specific.moment of inertia x1e4 kg m2 · explanation only0.0362 ×10^-4 kg·m²

Engineering context

Selection notes

01

Torque values are not interchangeable

Rated, repeated peak, start-stop, and emergency limits represent different duty conditions. Confirm your motion profile against the source definition.

02

Form changes integration scope

A component set and an assembled unit with the same ratio may have different mass, bearings, interfaces, and allowable external loads.