PREVIEW / NOT FOR MANUFACTURE

HIWIN Corporation · DATORKER DSH-AJ

DSH-32-100-AJ

Vendor-specific / unresolved harmonic reducer configuration with a 100:1 reduction ratio and solid shaft.

Vendor-specific / unresolvedconfigurationlimitedreviewed
Add to compare

This record is a source-backed research sample, not yet a verified orderable SKU.

Normalized data

Specifications

Values shown in standard units

Performance

Reduction ratio100 :1
Rated torque at input 2000r/minAt 2,000 rpm input137 Nm
Nominal output torqueNot published
Repeated peak torqueNot published
Peak torque at start/stop333 Nm
Maximum average load torque216 Nm
Maximum momentary torqueNot published
Instantaneous torque647 Nm
Emergency-stop torqueNot published
Maximum allowable peak torqueNot published
Maximum input speed — source generic4,800 rpm
Maximum input speed — greaseNot published
Maximum input speed — oilNot published
Average input speed limit — greaseNot published
Average input speed limit — oilNot published
Rated / nominal input speedNot published

Integration

Product formVendor-specific / unresolved
Vendor form labelSolid shaft type
Input configurationSolid shaft
Frame sizeVendor code · explanation only in v0.132
MassNot published
Input moment of inertiaNot published
Rated service lifeNot published

All source-labelled observations

Modelsource specific.frame size · explanation only32
Reduction Ratioreduction ratio · filter-eligible100
Rated torque at input 2000r/minrated torque at input speed · filter-eligible137 Nm
Peak torque at start/stopsource specific.peak torque at start stop nm · explanation only333 Nm
Permissible maximum value of average load torquemaximum average load torque · filter-eligible216 Nm
Instantaneous permissible max. torquesource specific.instantaneous max torque nm · explanation only647 Nm
Permissible maximum input speedmaximum input speed.unspecified lubricant · filter-eligible4800 rpm
Permissible average input speedpermissible average input speed.unspecified lubricant · filter-eligible3500 rpm

Engineering context

Selection notes

01

Torque values are not interchangeable

Rated, repeated peak, start-stop, and emergency limits represent different duty conditions. Confirm your motion profile against the source definition.

02

Form changes integration scope

A component set and an assembled unit with the same ratio may have different mass, bearings, interfaces, and allowable external loads.