PREVIEW / NOT FOR MANUFACTURE

Harmonic Drive LLC · CSG-2UK

CSG-25-50-2UK-A01

Complete unit harmonic reducer configuration with a 50:1 reduction ratio and input spline.

Complete unitconfigurationeligiblereviewed
Add to compare

This record is a source-backed research sample, not yet a verified orderable SKU.

Normalized data

Specifications

Values shown in standard units

Performance

Reduction ratio50 :1
Rated Torque at Input Speed 2000 rpmAt 2,000 rpm input51 Nm
Nominal output torqueNot published
Repeated peak torque127 Nm
Peak torque at start/stopNot published
Maximum average load torque72 Nm
Maximum momentary torque242 Nm
Instantaneous torqueNot published
Emergency-stop torqueNot published
Maximum allowable peak torqueNot published
Maximum input speed — source genericNot published
Maximum input speed — grease5,600 rpm
Maximum input speed — oilNot published
Average input speed limit — grease3,500 rpm
Average input speed limit — oilNot published
Rated / nominal input speedNot published

Integration

Product formComplete unit
Vendor form labelunit
Input configurationinput spline
Frame sizeVendor code · explanation only in v0.125
Mass2.2 kg
Input moment of inertia0.65 source scale
Rated service lifeNot published

All source-labelled observations

Sizesource specific.frame size · explanation only25
Ratioreduction ratio · filter-eligible50
Rated Torque at Input Speed 2000 rpmrated torque at input speed · filter-eligible51 Nm
Limit for Repeated Peak Torquesource specific.repeated peak torque nm · explanation only127 Nm
Limit for Average Torquemaximum average load torque · filter-eligible72 Nm
Limit for Momentary Peak Torquesource specific.momentary peak torque nm · explanation only242 Nm
Maximum Input Speed - Grease lubricantmaximum input speed.grease · filter-eligible5600 rpm
Limit for Average Input Speed - Grease lubricantpermissible average input speed.grease · filter-eligible3500 rpm
Moment of inertia (including input spline) Isource specific.input moment of inertia x1e4 kg m2 · explanation only0.65 ×10^-4 kg·m²
Massmass.exact · filter-eligible2.2 kg

Engineering context

Selection notes

01

Torque values are not interchangeable

Rated, repeated peak, start-stop, and emergency limits represent different duty conditions. Confirm your motion profile against the source definition.

02

Form changes integration scope

A component set and an assembled unit with the same ratio may have different mass, bearings, interfaces, and allowable external loads.